USA Catalog

HYPERTENSION AND ADRENAL FUNCTION - RIA

ACTH

24130/130 Tubes

Intended use

Quantitative determination of human Adrenocorticotrophic hormone ( ACTH)

Label

125 I

Method

RIA Double Antibody

Controls included

Two Levels

No. standard

6

Incubations

Overnight

Sample type

EDTA Plasma

Sample size

100 µL

Comments

For In Vitro Diagnostic Use.

ACTH IRMA

27065/65 Beads

Intended use

Quantitative determination of human Adrenocorticotrophic hormone ( ACTH)

Label

125 I

Method

RIA IRMA Bead

Controls included

Three Levels

No. standard

6

Incubations

Overnight

Feature & benefits

Highly sensitive and specific.

Sample type

EDTA Plasma

Sample size

200 µL

Comments

For In Vitro Diagnostic Use.

ACTH IRMA

27130/130 Beads

Intended use

Quantitative determination of human Adrenocorticotrophic hormone ( ACTH)

Label

125 I

Method

RIA IRMA Bead

Controls included

Three Levels

No. standard

6

Incubations

Overnight

Feature & benefits

Highly sensitive and specific.

Sample type

EDTA Plasma

Sample size

200 µL

Comments

For In Vitro Diagnostic Use.

GammaCoat™ Cortisol

CA1529/100 Tubes

Intended use

Quantitative determination of Cortisol (Hydrocortisone)

Label

125 I

Method

RIA Coated Tube

Controls included

Not Included

No. standard

6

Incubations

45 min/37°C

Sample type

Serum/Plasma/Urine

Sample size

10 µL

Comments

For In Vitro Diagnostic Use.

GammaCoat™ Cortisol

CA1549/500 Tubes

Intended use

Quantitative determination of Cortisol (Hydrocortisone)

Label

125 I

Method

RIA Coated Tube

Controls included

Not Included

No. standard

6

Incubations

45 min/37°C

Sample type

Serum/Plasma/Urine

Sample size

10 µL

Comments

For In Vitro Diagnostic Use.

GammaCoat™ Plasma Renin Activity

CA1533/100 Tubes

Intended use

Quantitative determination of Plasma Renin Acitivity (PRA) by the Radioimmunoassay of generated Angiotensin I.

Label

125 I

Method

RIA Coated Tube

Controls included

One Level

No. standard

6

Incubations

3 hrs/RT

Sample type

EDTA Plasma

Sample size

1000 µL extraction

Comments

For In Vitro Diagnostic Use.

GammaCoat™ Plasma Renin Activity

CA1553/500 Tubes

Intended use

Quantitative determination of Plasma Renin Acitivity (PRA) by the Radioimmunoassay of generated Angiotensin I.

Label

125 I

Method

RIA Coated Tube

Controls included

One Level

No. standard

6

Incubations

3 hrs/RT

Sample type

EDTA Plasma

Sample size

1000 µL

Comments

For In Vitro Diagnostic Use.

Radioactivity

10 microliters Ci