Select a product:
Infectious disease
Bone and mineral metabolism
Endocrinology
Liaison ®
Spq protein
Autoimmunity
Therapeutic drug monitoring
USA Catalog
SERUM PROTEIN MEASUREMENT
Alpha-1-Antitrypsin Antibody Reagent Set II |
86079/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for AAT is designed for quantitative determination of AAT by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Controls included with corresponding calibrator/control set. |
Kit components |
1. AAT Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Alpha-1-Antitrypsin SPQ™ II Kit |
86043/ Liquid |
Intended use |
Quantitative determination of AAT in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for AAT (86079). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
C3 Antibody Reagent Set II |
86077/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for IgM is designed for quantitative determination of IgM by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. C3 Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
C3 SPQ™ II Kit |
86041/ Liquid |
Intended use |
Quantitative determination of C3 in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for C3 (86077). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
C4 Antibody Reagent Set II |
86078/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for C4 is designed for quantitative determination of C4 by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. C4 Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
C4 SPQ™ II Kit |
86042/ Liquid |
Intended use |
Quantitative determination of C4 in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for C4 (86078). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Calibration/Control Set |
86100/ Liquid |
Method |
Nephelometric/Turbidimetric |
Controls included |
Normal level control included in set. |
No. standard |
5 |
Feature & benefits |
Calibration/Control Set contains 5 standards and 1 control with values assigned for use with Alpha-1-Antitrypsin, C3, C4, Haptoglobin, IgA, IgM, IgG, and Transferrin. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Haptoglobin Antibody Reagent Set II |
86081/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Haptoglobin is designed for quantitative determination of haptoglobin by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. HPT Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Haptoglobin SPQ™ II Kit |
86044/ Liquid |
Intended use |
Quantitative determination of haptoglobin in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for HPT (86081). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
High Sensitive CRP Calibration Set A |
86021 |
Intended use |
The SPQ Calibration Set for High Sensitve CRP is designed for quantitative determination of C-reactive protein by immunoprecipitation analysis in conjunction with the SPQ Antibody Reagent Set |
Method |
Nephelometric/Turbidmetric |
No. standard |
5 |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. Additional control material may be purchased separately. No sample pre-treatment required. |
Measuring range |
.05-20 mg/L |
Sample type |
Serum |
High Sensitive CRP Calibration Set B |
86022 |
Intended use |
The SPQ Calibration Set for High Sensitve CRP is designed for quantitative determination of C-reactive protein by immunoprecipitation analysis in conjunction with the SPQ Antibody Reagent Set |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. Additional control material may be purchased separately. No sample pre-treatment required. |
Measuring range |
.05-10 mg/L |
Sample type |
Serum |
IgA Antibody Reagent Set II |
86075/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for IgA is designed for quantitative determination of IgA by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. IgA Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
IgA SPQ™ II Kit |
86048/ Liquid |
Intended use |
Quantitative determination of IgA in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for IgA (86075). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capability. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is m |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
IgG Antibody Reagent Set II |
86074/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for IgG is designed for quantitative determination of IgG by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. IgG Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
IgG SPQ™ II Kit |
86047/ Liquid |
Intended use |
Quantitative determination of IgG in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for IgG (86074). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capability. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is m |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
IgM Antibody Reagent Set II |
86076/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for C3 is designed for quantitative determination of C3 by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. IgM Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
IgM SPQ™ II Kit |
86040/ Liquid |
Intended use |
Quantitative determination of IgM in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for IgM (86076). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Microalbumin Antibody Reagent Set II |
86072/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for microalbumin is designed for the quantitative determination of human urinary albumin by automated immunopreciptin analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. Microalbumin Antibody Reagent 2. Polymer Diluent II 3. Diluent B |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Urine |
Comments |
For In Vitro Diagnostic Use. |
Microalbumin Calibration/Control Set |
86106/ Liquid |
Intended use |
The SPQ™ Calibration/Control Set for Microalbumin is designed for quantitative determination of human urinary albumin in conjunction with the SPQ™ Antibody Reagent Set for Microalbumin. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
6 |
Kit components |
1. Microalbumin Calibration Set 2.0 Microalbumin control |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Urine |
Comments |
For In Vitro Diagnostic Use. |
Microalbumin SPQ™ II Kit |
86094/ Liquid |
Intended use |
Quantitative determination of microalbumin in human urine by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
6 |
Kit components |
Antibody Reagent Set II for Microalbumin (86072). Microalbumin Calibrator/Control Set (86106). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. No sample pretreatment required. Components may also be ordered separately for additional cost savings. |
Sample type |
Urine |
Comments |
For In Vitro Diagnostic Use. |
Prealbumin Antibody Reagent Set II |
86073/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Prealbumin is designed for quantitative determination of prealbumin by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. Prealbumin Antibody Reagent 2. Polymer Diluent I |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Prealbumin Calibration/Control Set |
86107/ Liquid |
Intended use |
The SPQ™ Calibration/Control Set for Prealbumin is designed for quantitative determination of prealbumin in human serum by immunoprecipitation analysis in conjunction with the SPQ™ Antibody Reagent Set for Prealbumin. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
1. Prealbumin Calibration Set 2. Control for Prealbumin |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Prealbumin SPQ™ II Kit |
86095/ Liquid |
Intended use |
Quantitative determination of prealbumin in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for Prealbumin (86073). Prealbumin Calibrator/Control Set (86107). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. No sample pretreatment required. Components may also be ordered separately for additional cost savings. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Transferrin Antibody Reagent Set II |
86082/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Transferrin is designed for quantitative determination of transferrin by immunoprecipitation. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Controls included with corresponding calibrator/control set. |
Kit components |
1. TRF Antibody Reagent 2. Polymer Diluent 3. Saline Diluent |
Feature & benefits |
Liquid reagents. Two reagent antibody system designed for instrument capable of handling on-line reagent dilution. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Transferrin SPQ™ II Kit |
86045/ Liquid |
Intended use |
Quantitative determination of transferrin in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for TRF (86082). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. Calibrator/Control Set is |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |
Transferrin SPQ™ III Kit |
86117/Liquid |
Intended use |
Quantitative determination of transferrin in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set III for TRF (88711). SPQ™ Calibrator/Control Set (86100). |
Feature & benefits |
Liquid reagents. Designed for use with Hitachi instrument. No sample pre-treatment required. Components may also be purchased separately for additional cost savings. |
Sample type |
Serum |
Comments |
For In Vitro Diagnostic Use. |


