Select a product:
Infectious disease
Bone and mineral metabolism
Endocrinology
Liaison ®
Spq protein
Autoimmunity
Therapeutic drug monitoring
USA Catalog
CARDIAC RISK ASSESSMENT
APO A-1 Antibody Reagent Set II |
86059/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Apolipoprotein A-1 is designed for the quantitative determination of Apo A-1 levels in human serum or plasma by immunoprecipitin analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
No. standard |
5 |
Kit components |
1. Apo A-1 Antibody Reagent 2. Apo A-1 Antibody Diluent 3. Diluent A |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
APO A-1 Calibration/Control Set |
86102/ Liquid |
Intended use |
The SPQ™ Calibration/Control Set for Apolipoprotein A-1 (APO A-1) is designed to assist in the quantitative determination of APO A-1 in human serum or plasma in conjunction with the SPQ™ Antibody Reagent Set II for APO A-1. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
1. Calibration Set for Apolipoprotein A-1 2. Control for Apo A-1 |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
APO A-1 SPQ™ II Kit |
86070/ Liquid |
Intended use |
Quantitative determination of Apo A-1 in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for Apo A-1 (86059). Apo A-1 Calibrator/Control Set (86102). |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
APO B Antibody Reagent Set II |
86060/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Apolipoprotein B is designed for the quantitative determination of Apo B levels in human serum or plasma by immunoprecipitin analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Control included with corresponding calibrator/control set. |
Kit components |
1. Apo B Antibody Reagent 2. Polymer Diluent 3. Diluent A |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
APO B Calibration/Control Set |
86103/ Liquid |
Intended use |
The SPQ™ Calibration/Control Set for Apolipoprotein B (APO B) is designed to assist in the quantitative determination of APO B in human serum or plasma in conjunction with the SPQ™ Antibody Reagent Set II for APO B. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
1. Calibration Set for Apo-B 2. Control for Apo-B |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
APO B SPQ™ II Kit |
86071/ Liquid |
Intended use |
Quantitative determination of Apo B in human serum by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for Apo B (86060). Apo B Calibrator/Control Set (86103). |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
Fibrinogen Antibody Reagent Set II |
86086/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Fibrinogen is designed for the quantitative determination of fibrinogen levels in human plasma by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Controls included with corresponding calibrator/control set. |
Kit components |
1. Fibrinogen Antibody Reagent 2. Polymer Diluent III 3. Diluent A |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Test systems may also be ordered as the separate kit components for additional cost savings. |
Sample type |
Citrated Plasma/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
Fibrinogen Calibration/Control Set |
86116/ Lyophilized |
Intended use |
The SPQ™ Calibration/Control Set for Fibrinogen is designed to assist in the quantitative determination of fibrinogen in human plasma in conjunction with the SPQ™ Antibody Reagent Set II for Fibrinogen. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
1 |
Kit components |
1. Calibrator for Fibrinogen 2. Control for Fibrinogen |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent and sample dilution capabilities. Additional control material may be purchased separately. |
Sample type |
Citrated Plasma/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
Fibrinogen SPQ™ II Kit |
86113/ Liquid |
Intended use |
Quantitative determination of fibrinogen in human plasma by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
One Level |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for Fibrinogen (86086). Fibrinogen Calibrator/Control Set (86116). |
Feature & benefits |
For use with instrument systems with on-line reagent and sample dilution capabilities. Components may also be ordered separately for additional cost savings. |
Sample type |
Citrated Plasma/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
High Sensitive CRP Reagent Set |
86119 |
Intended use |
The SPQ High Sensitive CRP Assay is an in vitro diagnostic test for the quantitative determination of C-reactive protein in human serum and plasma samples with automated clinical chemistry analyzer. |
Method |
Nephelometric/Turbidmetric |
Kit components |
High Sensitive CRP Antibody Reagent and Diluent |
Feature & benefits |
Liquid Reagents. Two reagent antibody system designed for instrument capable of handling on-line dilution. No sample pre-treatment required. |
Sample type |
Serum |
Lipoprotein (a) Antibody Reagent Set II |
86084/ Liquid |
Intended use |
The SPQ™ Antibody Reagent Set II for Lp(a) is designed for the quantitative determination of Lp(a) levels in human serum or plasma by immunoprecipitin analysis. |
Method |
Nephelometric/Turbidimetric |
Kit components |
1. Lp(a) Antibody Reagent 2. Lp(a) Diluent |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent dilution capabilities. Test systems may also be ordered as the separate kit components for additional cost savings. No sample pre-treatment |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
Lipoprotein (a) Calibration/Control Set |
86114/ Liquid |
Intended use |
The SPQ™ Calibration/Control Set for Lp(a) is designed for quantitative determination of lipoprotein(a) in human serum or plasma in conjunction with the SPQ™ Antibody Reagent Set II for Lp(a). |
Method |
Nephelometric/Turbidimetric |
Controls included |
Two Levels |
No. standard |
5 |
Kit components |
1. Calibration Set for Lipoprotein (a) 2. Controls for Lp(a) |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. No sample pretreatment required. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
Lipoprotein (a) SPQ™ II Kit |
86111/ Liquid |
Intended use |
Quantitative determination of Lp(a) in human serum/plasma by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
Controls included |
Two Levels |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for Lp(a) (86084). Lp(a) Calibrator/Control Set (86114). |
Feature & benefits |
Liquid reagents. For use on instruments with on-line reagent dilution capabilities. Components may also be ordered separately for additional cost savings. |
Sample type |
Serum/EDTA Plasma |
Comments |
For In Vitro Diagnostic Use. |
Wide Range CRP Calibration Set |
86031 |
Intended use |
The SPQ Calibration Set for High Sensitive CRP is designed for quantitative determination of C-reative protein by immunoprecipitation analysis in conjunction with the SPQ Antibody Reagent Set |
Method |
Nephelometric/Turbidmetric |
No. standard |
5 |
Feature & benefits |
Liquid reagents. For use with instrument systems with on-line reagent dilution capabilities. Additional control material may be purchased separately. No sample pre-treatment required |
Measuring range |
2.5 - 160 mg/L = 0.25 - 16mg/dL |
Sample type |
Serum |
Wide Range CRP Reagent Set |
86030 |
Intended use |
The SPQ High Sensitive CRP Assay is an in vitro diagnostic test for the quantitative determination of C-reative protein in human serum samples with automated clinical chemistry analyzer. |
Method |
Nephelometric/Turbidmetric |
Kit components |
CRP Antibody Reagent and Diluent |
Feature & benefits |
Liquid Reagents. Two reagent antibody system designed for instrument capable of handling on-line dilution treatment required. |
Sample type |
Serum |


