Select a product:
Infectious disease
Bone and mineral metabolism
Endocrinology
Oncology
Liaison ®
Spq protein
Autoimmunity
Therapeutic drug monitoring
Cns
International Catalog
CARDIAC RISK ASSESSMENT
APO A-1 SPQ II Kit |
86070 Liquid |
Intended use |
Quantitative determination of APO A-1 by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for APO A-1 (86059). APO A-1 Calibration/Control Set (86102) |
Feature & benefits |
Liquid reagents. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA-Plasma |
APO A-1 Antibody Reagent Set II |
86059 Liquid |
Intended use |
The SPQ Antibody Reagent Set II for Apolipoprotein A-1 is designed for the quantitative determination of APO A-1 levels by immunoprecipitin analysis. |
Method |
Nephelometric/Turbidimetric |
Kit components |
APO A-1 Antibody Reagent. APO A-1 Antibody Diluent. Diluent A |
Feature & benefits |
Liquid reagents.Additional control material may be purchased separately. |
Sample type |
Serum/EDTA-Plasma |
APO A-1 Calibration/Control Set |
86102 Liquid |
Intended use |
The SPQ Calibration/Control Set for Apolipoprotein A-1 (APO A-1) is designed for the quantitative determination of APO A-1 in conjunction with the SPQ Antibody Reagent Set II for APO A-1. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Calibration Set for Apolipoprotein A-1. Control for APO A-1 |
Feature & benefits |
Liquid reagents. Additional control material may be purchased separately. |
Sample type |
Serum |
APO B SPQ II Kit |
86071 Liquid |
Intended use |
Quantitative determination of APO B by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for APO B (86060). APO B Calibrator/Control Set (86103) |
Feature & benefits |
Liquid reagents. Components may also be ordered separately. |
Sample type |
Serum/EDTA-Plasma |
APO B Antibody Reagent Set II |
86060 Liquid |
Intended use |
The SPQ Antibody Reagent Set II for Apolipoprotein B is designed for the quantitative determination of APO B levels by immunoprecipitin analysis. |
Method |
Nephelometric/Turbidimetric |
Kit components |
APO B Antibody Reagent. Polymer Diluent. Diluent A |
Feature & benefits |
Liquid reagents. |
Sample type |
Serum/EDTA-Plasma |
APO B Calibration/Control Set |
86103 Liquid |
Intended use |
The SPQ Calibration/Control Set for Apolipoprotein B (APO B) is designed for the quantitative determination of APO B in conjunction with the SPQ Antibody Reagent Set II for APO B. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Calibration Set for Apo-B. Control for Apo-B |
Feature & benefits |
Liquid reagents.Additional control material may be purchased separately. |
Sample type |
Serum |
Fibrinogen SPQ II Kit |
86113 Liquid |
Intended use |
Quantitative determination of Fibrinogen by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 (serial dilution) |
Kit components |
Antibody Reagent Set II for Fibrinogen (86086). Fibrinogen Calibration/Control Set (86116) |
Feature & benefits |
Components may also be ordered separately. |
Sample type |
Citrated Plasma/EDTA-Plasma |
Fibrinogen Antibody Reagent Set II |
86086 Liquid |
Intended use |
The SPQ Antibody Reagent Set II for Fibrinogen is designed for the quantitative determination of fibrinogen levels by immunoprecipitation analysis. |
Method |
Nephelometric/Turbidimetric |
Kit components |
Fibrinogen Antibody Reagent. Polymer Diluent III. Diluent A |
Feature & benefits |
Liquid reagents.Test systems may also be ordered as the separate kit components. |
Sample type |
Citrated Plasma/EDTA-Plasma |
Fibrinogen Calibration/Control Set |
86116 Lyophilized |
Intended use |
The SPQ Calibration/Control Set for Fibrinogen is designed to assist in the quantitative determination of fibrinogen in conjunction with the SPQ Antibody Reagent Set II for Fibrinogen. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 (serial dilution) |
Kit components |
Calibrator for Fibrinogen. Control for Fibrinogen |
Feature & benefits |
Liquid reagents. Additional control material may be purchased separately. |
Sample type |
Citrated Plasma/EDTA-Plasma |
Lipoprotein(a) SPQ II Kit |
86111 Liquid |
Intended use |
Quantitative determination of Lp(a) by immunoprecipitin methods. |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Antibody Reagent Set II for Lp(a) (86084). Lp(a) Calibration/Control Set (86114) |
Feature & benefits |
Liquid reagents. Components may also be ordered separately. |
Sample type |
Serum/EDTA-Plasma |
Lipoprotein(a) Antibody Reagent Set II |
86084 Liquid |
Intended use |
The SPQ Antibody Reagent Set II for Lp(a) is designed for the quantitative determination of Lp(a) levels by immunoprecipitin analysis. |
Method |
Nephelometric/Turbidimetric |
Kit components |
Lp(a) Antibody Reagent. Lp(a) Diluent |
Feature & benefits |
Liquid reagents.Test systems may also be ordered as the separate kit components. No sample pre-treatment is necessary. |
Sample type |
Serum/EDTA-Plasma |
Lipoprotein(a) Calibration/Control Set |
86114 Liquid |
Intended use |
The SPQ Calibration/Control Set for Lp(a) is designed for quantitative determination of Lipoprotein(a) in human serum or plasma in conjunction with the SPQ Antibody Reagent Set II for Lp(a). |
Method |
Nephelometric/Turbidimetric |
No. standard |
5 |
Kit components |
Calibration Set for Lipoprotein(a). Controls for Lp(a) |
Feature & benefits |
Liquid reagents. No sample pre-treatment required. Additional control material may be purchased separately. |
Sample type |
Serum/EDTA-Plasma |


