International Catalog

ONCOLOGY

LIAISON® Calcitonin II Gen Specimen Diluent

310652

Intended use

For diluting specimens with levels of Calcitonin > 2000 pg/mL

LIAISON® Calcitonin II Gen

310650

Intended use

For the quantitative determination of calcitonin in human serum

Material provided

Reagent Integral for 100 determinations

Method

Direct, two-site, sandwich type immunolumiometric assay using directly coated magnetic microparticle

Detection limit

1 pg/mL

Calibrators

Included

Incubations

30 min

Measuring range

1.0-2000 pg/mL

Sample type

Serum

Sample size

200 µL

LIAISON® Thymidine Kinase

310960

Intended use

For the quantitative determination of the Thymidine Kinase enzymatic activity

Label

LIAISON® Thymidine Kinase

Material provided

Reagent for 100 determinations

Method

Indirect, modified 2-step, competitive chemiluminescent immunoassay

Calibrators

Included

Incubations

60 min

Sample type

Serum, and EDTA Plasma

LIAISON® Thymidine Kinase Specimen Diluent Set

310962

Intended use

For diluting specimens with high levels of Thymidine Kinase > 100 U/L.

LIAISON® CEA

314311

Intended use

For the quantitative determination of Carcinoembryonic Antigen (CEA).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.2 ng/mL (MRC 73/601)

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

0.2-1000 ng/mL

Sample type

Serum/Plasma

Sample size

50 µL

LIAISON® AFP

314471

Intended use

For the quantitative determination of Alpha-Fetoprotein (AFP).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.2 IU/mL (MRC 72/225)

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

0.2-1000 IU/mL

Sample type

Serum/Plasma/Amniotic Fluid

Sample size

25 µL

LIAISON® CA 19-9™

314171

Intended use

For the quantitative determination of 1116-NS-19-9 Defined Antigen (CA 19-9).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.3 U/mL.

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

0.3-1000 U/mL

Sample type

Serum/Plasma

Sample size

100 µL

LIAISON® CA 125 II™

314211

Intended use

For the quantitative determination of OC125 Defined Antigen (CA 125).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.2 U/mL.

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

0.2-1000 U/mL

Sample type

Serum/Plasma

Sample size

100 µL

LIAISON® CA 15-3®

314301

Intended use

For the quantitative determination of DF3 Defined Antigen (CA 15-3).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.3 U/mL.

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

0.3-1000 U/mL

Sample type

Serum/Plasma

Sample size

10 µL

LIAISON® PSA

314381

Intended use

For the quantitative determination of Total Prostate-Specific Antigen (T-PSA).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.09 ng/mL (NIBSC 96/670)

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

0.09-300 ng/mL

Sample type

Serum/Plasma

Sample size

50 µL

LIAISON® fPSA

314391

Intended use

For the quantitative determination of free Prostate-Specific Antigen (f-PSA).

Material provided

Reagent Integral for 100 determinations.

Method

1-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.04 ng/mL.

Calibrators

and Diluent included

Incubations

10 min

Measuring range

0.04-25 ng/mL

Sample type

Serum/Plasma

Sample size

50 µL

Comments

Not available in all countreis

LIAISON® Ferritin

313551

Intended use

For the quantitative determination of Ferritin.

Material provided

Reagent Integral for 100 determinations.

Method

1-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.5 ng/mL (NIBSC 80/578)

Calibrators

Included

Incubations

10 min

Measuring range

0.5-3000 ng/mL

Sample type

Serum/Plasma

Sample size

10 µL

LIAISON® TPA® -M

314121

Intended use

For the quantitative determination of Tissue Polypeptide Antigen (TPA).

Material provided

Reagent Integral for 100 determinations.

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

2.0 U/L.

Calibrators

and Diluent included

Incubations

20 min (10 min + 10 min)

Measuring range

2-4000 U/L

Sample type

Serum

Sample size

100 µL

LIAISON® NSE

314561

Intended use

For the quantitative determination of Neuron-Specific Enolase (NSE).

Material provided

Reagent Integral for 100 determinations.

Method

1-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.04 µg/L.

Calibrators

and Diluent included

Incubations

10 min

Measuring range

0.04-200 µg/L

Sample type

Serum

Sample size

25 µL

LIAISON® S100

314701

Intended use

For the quantitative determination of Protein S-100 B.

Material provided

Reagent Integral for 100 determinations.Diluent included

Method

2-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.02 µg/L.

Calibrators

extra

Incubations

20 min (10 min + 10 min)

Measuring range

0.02-30 µg/L

Sample type

Serum/CSF

Sample size

100 µL

LIAISON® β2-Microglobulin

314501

Intended use

For the quantitative determination of β2-Microglobulin

Material provided

Reagent Integral for 100 determinations.

Method

1-step immunoluminometric sandwich assay using directly coated magnetic microparticles

Detection limit

0.12 mg/L.

Calibrators

included

Incubations

10 min

Measuring range

0.12-40 mg/L

Sample type

Serum/Plasma/Urine

Sample size

10 µL

LIAISON® Calcitonin

310940

Intended use

For the quantitative determination of calcitonin in human serum

Material provided

Reagent Integral for 100 determinations

Method

Direct, two-site, sandwich type immunolumiometric assay using directly caoted magnetic microparticle

Detection limit

1 pg/mL

Calibrators

Included

Incubations

30 min

Measuring range

1.0-2000 pg/mL

Sample type

Serum

Sample size

150 µL